Belkin bulldog software




















If Belkin is the subject of a claim, becomes involved in a legal proceeding, or suffers any economic loss or damage as a result of your violation of this Agreement, to the extent permitted by law, you will be responsible for compensating Belkin for the full amount of its loss, as well as any reasonable amounts Belkin incurs in lawyers' fees, expenses and court costs, except to the extent that Belkin contributed to the loss or damage.

Once accepted, this Agreement remains in effect until terminated. The limited license in this Agreement will be automatically terminated if you fail to comply with any of the terms and conditions in this Agreement.

You agree that upon such termination, you will immediately destroy all programs and documentation that relate to the Software, including all copies made or obtained by you, and otherwise cease use of the Software.

If the Software has been installed on a personal computer or mobile device, you must uninstall the Software immediately. If the Software is software or firmware embedded on a Product, you must stop using the Product. All provisions of this Agreement except for Section 1 and the limited warranty in Section 12 the first paragraph will survive termination.

In addition to these remedies a "consumer" within the meaning of the CGA may claim for any reasonably foreseeable loss other than loss or damage through reduction of value of the goods that results from the initial problem. To make a claim under this Limited Warranty, return the defective media along with the sales receipt directly to Belkin at the following address: Belkin International, Inc. This Limited Warranty is void if failure of the media has resulted from accident, abuse, or misapplication.

Any replacement media will be warranted for the remainder of the original Warranty Period or thirty 30 days, whichever is longer.

In relation to consumers who are entitled to the benefit of the CGA, the media on which Software is provided comes with guarantees that cannot be excluded under New Zealand law, and this Limited Warranty is in addition to any statutory rights such consumers may have under New Zealand law.

This Limited Warranty does not apply in Australia. Consumers in Australia have statutory rights in relation to the Software and media on which the Software is provided under the Australian Consumer Law. To the extent warranties cannot be disclaimed or excluded, they are limited to the duration of the relevant Warranty Period. It is your responsibility to back up your system, including without limitation, any material, information or data that you may use or possess in connection with the Product or Software, and Belkin shall have no liability for your failure to back up your system or any material, information or data.

Some Belkin Products and Software may monitor energy consumption in the home. Belkin does not guarantee or promise any specific level of energy savings or other monetary benefit from the use of the Products or Software or any other feature. From time to time, Belkin may use the Software to provide you with information that is unique to you and your energy usage and suggests an opportunity to save money on energy bills if you adopt suggestions or features of the Product or Software.

You acknowledge that this information is not a guarantee of actual savings, and you agree not to seek monetary or other remedies from Belkin if your savings differs. We cannot guarantee that it is correct or up to date. In cases where it is critical, accessing information through the Software is not a substitute for direct access of the information in the home.

The warranties and remedies set out in this Agreement are exclusive, and, to the extent permitted by law, in lieu of all others oral or written, express or implied. You agree to strictly comply with all export control laws and regulations and agree not to export, re-export, divert, transfer or disclose any portion of the Software or any related technical information or materials, directly or indirectly, in violation of any applicable export law or regulation.

All U. Government users acquire the Software and user documentation with only those rights herein that apply to non-governmental customers. Use of either the Software or user documentation or both constitutes agreement by the U.

If any portion of this Agreement or any of its terms is found to be void or unenforceable by law in a particular jurisdiction, such portion or terms shall be interpreted and enforced to the maximum extent allowed in such jurisdiction, and the remaining provisions or any part thereof will remain in full force and effect.

This Agreement constitutes the entire agreement between Belkin and you with respect to the Software and your use thereof and supersedes any conflicting or additional terms contained in any purchase order or elsewhere. No provision of this Agreement may be waived, modified or superseded except by a written instrument accepted by Belkin and you. However, the Belkin Privacy Policy referenced herein is subject to change in the manner described in that document.

Belkin may provide translations of this Agreement as a convenience to users. However, in the event of a conflict or inconsistency between the English and any non-English versions, the English version of this Agreement shall govern, to the extent not prohibited by local law in your jurisdiction.

Any suppliers of Belkin shall be direct and intended third-party beneficiaries of this Agreement, including without limitation with respect to the disclaimers of warranties and limitations on liability set forth herein.

Other than as set forth in the preceding sentence, a person or entity who is not a party to this Agreement shall not have any right to enforce any term of this Agreement. I found that if this register is non-zero, then the Bulldog software initiates an immediate shutdown. But it does not specify the reason. Setting this register has no apparent effect; subsequents reads will still return 0. The current AC input voltage in 0. Note that this value is non-zero as long as AC power is present, even during a battery test.

The current AC input frequency in 0. The current UPS temperature, in degrees C. My UPS does not actually implement this register, but the Bulldog software recognizes it. The current AC output voltage in 0. The current AC output frequency in 0. On my system, it takes value This register holds the following flags. Since some of these conditions rarely occur, I am not sure whether my UPS implements all of them; anyway, the Bulldog Monitor recognizes them.

This flag is not set during battery self-tests unless the power fails at the same time. The Bulldog driver uses the AC Failure flag as the sole means to determine whether to initiate shutdown procedures, and also as the sole means to determine the drawing of the "Diagram" display, as well as the AC Source status line in the "Main" display.

The Buzzer status flag is somewhat strange. The Bulldog software uses this flag as the basis for the "Buzzer Alarm" status flag in the "Status" display , with the annoying effect that this flag is almost always on, even when the buzzer is not ringing.

Maybe this is a bug in my UPS's firmware. In any case, it seems that the buzzer is actually ringing if and only if flag 0x in register 22 and flag 0x20 in register 23 are both set. If 0x is not set, this is not necessarily the case unless, strangely, register 1f was 0x00 or 0x20 during startup. It is not clear to what extent this behavior means anything, and to what extent it just reveals idiosyncracies in the Bulldog software. This is strictly speaking wrong.

Note that after switching from battery powered mode to AC powered mode, it takes a few seconds until the battery starts being charged, i. A battery status flag of 0x00 has also been observed, for instance, when turning off the load during a test so that the battery is neither charging nor discharging. Notes: here is what happens if AC power gets disconnected and we continue the load. First, the UPS will switch to battery power and the buzzer will beep every 10 seconds unless disabled.

The UPS status becomes 0x or 0x if the buzzer is disabled. The battery status becomes 0x The battery voltage and battery level will decrease continually. When the battery level falls below 15, the "battery low" flag will come on, thus the battery status become 0x At the same time the buzzer will start ringing fast and can no longer be disabled.

The UPS status is unchanged at 0x The battery voltage and level will continue to drop, and the UPS will continue to supply power, even when the battery level reaches 0. Finally, after the battery level has been 0 for a while, the UPS turns its load off and does a "soft shutdown". At this point, the battery status becomes 0x40 battery depleted and the UPS status becomes 0xa AC failure and awaiting power.

This is the only scenario in which I have observed a "soft shutdown", as indicated by UPS status flag 0x Web Author Plus allows you to create professional looking web pages using HTML plus additional built-in authoring commands.

All rights reserved. This is the place to come for a first look at the hottest new software. Shareware companies need your support. Beta testing is a unique opportunity to try the latest programs and provide feedback directly to the program developers. The final version of many programs is often determined by suggestions from testers like you.

Shareware Junction lets you choose from a variety of these products - all in one convenient location. Use of this site subject to Terms and Privacy Policy. System Requirements User Reviews. Screen Shot. Description Shutdown Management Software.. Download Now.

Bulldog Plus v. Category: Developer: Belkin - Download - Free. I am using the software for research, good work! Boosting productivity of my team by allowing them to input ideas and get the response from other Good software.

I absolutely love this. Keep updated!